FS#785 - Hatch at scale 1/10 not completed on 500 mm x 500 mm square?

Attached to Project: QCAD
Opened by -- (clive) - Tuesday, 12 March 2013, 17:10 GMT
Last edited by Andrew (andrew) - Monday, 16 December 2013, 12:52 GMT
Task Type Bug Report
Category Main
Status Closed
Assigned To Andrew (andrew)
Operating System Windows (All)
Severity Low
Priority Normal
Reported Version Development
Due in Version Undecided
Due Date Undecided
Percent Complete 100%
Votes 0
Private No

Details

Windows 7-64
3.0.8

I’ve not been able to hatch a simple Brick pattern at a scale of 1/10 on anything larger that 500 mm x 500 mm.

*Scale of 1:1 works fine
*Scale of 1/10 works fine on Squares 400 mm x 400 mm or less!

To reproduce:
1. Draw square of 500 x 500 mm.
2. Select and execute Hatch command using Brick pattern (but I suspect the result will be the same with any pattern).
3. Result in selection states a Hatch but no hatch is present!

Please see attached image:

This task depends upon

Closed by  Andrew (andrew)
Monday, 16 December 2013, 12:52 GMT
Reason for closing:  Won't fix
Comment by -- (clive) - Tuesday, 12 March 2013, 19:10 GMT

Edit: Should read scale 1/20, but I have noticed that on some larger areas a scale of 1/10 is not working either!

Is there a limit in the size area for using hatches in general in QCAD?

Comment by Andrew (andrew) - Tuesday, 12 March 2013, 19:36 GMT

There is a timeout of 5 seconds for generating a hatch. This is to make sure the program does not freeze for hours if the user enters for example a factor of 0.0001.
The timeout can only be adjusted by editing the QCAD configuration file directly at this point. In section 'GraphicsView', add a value for MaxHatchTime, for example for a timeout of one minute (= 60 seconds = 60000 milliseconds):

[GraphicsView]
MaxHatchTime = 60000

The configuration file is called QCAD3.ini or QCAD3.conf and under Windows located under C:\Users\username\AppData\Roaming\RibbonSoft\

Comment by -- (clive) - Tuesday, 12 March 2013, 20:01 GMT

Great, thanks Andrew, that's got it ! Useful tip to know.

Loading...